INSTALLATION INSTRUCTIONS
Cutout
4" (102 mm) –
4-1/4" (108 mm)
Install the Wall Material
Install water-resistant wallboard.
Cut out a 4" (102 mm) to 4-1/4" (108 mm) square at each bodyspray installation location.
Install the finished wall material.
Install the Pipe Nipple
NOTE: The minimum distance between the face of the elbow/tee and the surface of the finished wall should be
2-1/4" (57 mm). The measurement for typical installations is 2-3/4" (70 mm).
Remove the nipple.
Measure the distance from the face of the elbow/tee to the surface of the finished wall. Make any
adjustments as needed.
If your measurement is 2-1/4" (57 mm): use a close pipe nipple.
If your measurement is 2-3/4" (70 mm): use a 1-1/2" pipe nipple.
Handtighten the nipple into the elbow/tee.
Verify that the distance from the end of the nipple to the surface of the finished wall is at least 1-1/2"
(38 mm) and no more than 1-3/4" (44 mm).
Remove the nipple.
Apply thread sealant to the nipple and reinstall to the elbow/tee.
Run water through the system to flush out any debris.
1506293-2-A
5 of 23
3. INSTALL THE FINISHED WALL AND THE NIPPLE
4" (102 mm) –
4-1/4" (108 mm)
2-1/4" (57 mm) Min
Tee (or Elbow)
Questions? Problems? For additional assistance, please contact KALLISTA's Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or kallista.com.
Bodyspray
Finished Wall
Cutout
Nipple
4" (102 mm) –
4-1/4" (108 mm)