Descargar Imprimir esta página

Product Description; Technical Specifications - Cleco mPro300GCD-STO Manual Del Usuario

Ocultar thumbs Ver también para mPro300GCD-STO:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 36
1
EN
3

Product description

Controller for use in safety-critical tightening.
The controller is primarily used as a control and monitoring
unit for one or more tools at a workstation. Depending on
the peripheral devices that are procured, the controller can
also be installed outside of the work environment.
Software is already installed on the controller. The tighten-
ing settings must be carried out by a qualified person using
the controller or remote PC software (mProRemote) in
order to start fastening work. For further information
regarding software operation, please reference the Pro-
gramming Manual.
Nutrunner controllers with the suffix STO in the type name
are equipped with the STO safety function, see Chapter 9
STO safety function, Page 16.
4

Technical Specifications

Ambient Conditions
Features
Operation Site
Ambient Temperature
Storage Temperature
Type of Cooling
Relative Humidity
Working Height
Protection Class
DIN EN 60529
Protection Class
DIN EN61140
(VDE 0140-1)
Degree of Contamination
EN 61010
Transient Overvoltage
EN 61010
Maximum Shock
DIN EN 60068-2-27
Maximum Vibration
DIN EN 60068-2-5
1 Note the derating. See System Handbook NeoTek™
10
Data
Indoors
1
0...45 °C
-20...70 °C
Convection (self-cooling)
10...90 %
No Condensation
Up to 3000 m
1
Above Sea Level
IP42
I
2

CAT
15 G
59.6–160 Hz: 2 G
P2552HW | 2021-04
Power Supply
Features
Supply Voltage,
Single Phase
Rated Supply Current
Frequency
Peak Current
Rated Power
Idling
1 When operating outside the allowable voltage limits,
the integrated power supply enters a protection mode
and switches off. This protection mode can be reset
by restarting the nutrunner controller.
Safety Technology
Safety indices
Safety
STO
Safe start lockout (STO, Safe
function
Torque Off) in accordance with
EN 61800-5-2, with SIL 2
Safe start lockout (STO, Safe
Torque Off) in accordance with
EN ISO 13849-1, Category 3 and
PL d
SIL
SIL 2
Safety level (Safety Integrity
Level) in accordance with EN
61800-5-2
Category 3
Classification in the category is in
accordance with EN ISO 13849-1
PL
PL d
Performance Level is in accor-
dance with EN ISO 13849-1
DCavg
60%
Low, average diagnostic cover-
age (Average Diagnostic Cover-
age)
HFT
1
Hardware Failure Tolerance
SFF
> 60%
Safe Failure Fraction
PFH
9.1 E-10 1/h < 0.1% of SIL 2, Probability of
dangerous Failure per Hour
PFDav
7.9 E-05
0.8% of SIL 2, Probability of dan-
(T = 20 a)
gerous Failure on Demand
T
12
Proof Test Interval service life in
PTI
[months]
accordance with EN ISO 13849-1
MTTFd
> 2.000 a
HIGH, Mean time to dangerous
failure
Normative references
For product-relevant EC Directives, as well as the stan-
dards complied with, see the EC Declaration of Conformity.
Data
1
100–240 VAC ± 10%
2–1 A
50/60 Hz
16 A
1600 VA max.
40 VA
Apex Tool Group

Publicidad

loading