X41, X42 – E-Stop
Signal assignment see 9.2.2 Interface overview, Page 17.
STO Function
X42
OUT
X41
IN
Connectors – Internal power supply
Example:
Signal X9
Pin
I/O
12
11
10
Output
9
Output
8
Output
7
Output
6
Input
5
Input
4
Input
3
Input
2
1
Inputs
Internal 24 V power supply for the controller.
Pin 11 and 23 (common GND) serve as a "return line"
for the outputs.
Pin 11 and 23 must be connected to Pin 12 or 24 with
jumpers.
Apex Tool Group
X9, X10 – Input/Output
Digital I/O Interface
The required signal circuits are connected to these input/
8 Pin M12 Circular
output connectors. The signal groups are connected to the
Connector
power supply.
Pin
Socket
Name
Supply GND Int.
Supply GND I/O
O3
O2
O1
O0
I3
I2
I1
I0
Supply +24 V O
Supply +24 V Int.
Outputs
P2552HW | 2021-04
8 inputs/8 outputs, optically isolated for 24 V level
Output current: 500 mA per output, 1000 mA total
Note
A single device must not require a current of
more than 500 mA. The current monitor
switches off the output in the event of an
overcurrent.
Phoenix Mini Combicon MCD 1,5/12-G1F-3,81
X9
Signal X10
Pin
I/O
Name
24
Supply GND Int.
23
Supply GND I/O
22
Output
O7
21
Output
O6
20
Output
O5
19
Output
O4
18
Input
I7
17
Input
I6
16
Input
I5
15
Input
I4
14
Supply +24 V O
13
Supply +24 V Int.
Internal 24 V power supply for the controller
Pin 2 and 14 (common output) are the voltage source
for the inputs.
Pin 2 and 14 must be connected to Pin 1 or 13