6.2 DOMESTIC HOT WATER(DHW)
The parameters in "DOMESTIC HOT WATER(DHW)" can be set only
when the unit has DHW function and DHW is set available. If the unit has
no DHW function or DHW is set unavailable, "DOMESTIC HOT
WATER(DHW)" will not be displayed on the interface.
DOMESTIC HOT WATER(DHW) contains the following menu:
1) DISINFECT
2) FAST DHW
3) TANK HEATER
4) DHW PUMP
6.2.1 DISINFECT
The DISINFECT function is used to kill the legionella. The tank
temperature will reach 60~70°C forcely if the disinfect function is
activated(The disinfect temperature can be set in "FOR SERCICEMAN").
Go to "
" > '' DOMESTIC HOT WATER(DHW)'' > "DISINFECT". Press
''
'', the following page will appear:
DOMESTIC HOT WATER(DHW)
DIS-
FAST
TANK
INFECT
DHW
HEATER
CURRENT STATE
OPERATE DAY
START
ON/OFF
ON/OFF
33
DHW
PUMP
OFF
FRI
23:00