PRIMING THE PUMP(S)
Upon filling or refilling the spa, if a pump is operating and water is not flowing
from any of its jets, the pump may not be properly primed. To correct, refer to
the illustration below and perform the following procedures:
• Turn off power to the spa at the breaker and remove the equipment
compartment door.
• Loosen the union on the top of the pump(s) to allow the air to escape. When
water is present, hand-tighten the union.
• Turn power back on, activate the pump and check to make sure union is
tight enough to keep it from leaking. Re-install equipment door.
NOTE: Equipment compartment illustrated below will vary depending on
spa model.
PUMP
UNIONS
THE UNION FITTINGS IN THE EQUIPMENT COMPARTMENT MAY LOOSEN
DURING TRANSPORTATION. TO AVOID LEAKS, PLEASE CHECK TO MAKE
English
Spanish
PUMP
UNIONS
IMPORTANT
SURE THESE ARE HAND-TIGHT
PRIOR TO FILLING YOUR SPA.
Page 7
French
HEATER
UNIONS
Getting Started