9.3.3 Pump performance

Dosing flow and maximum counterpressure
The values in the table below apply to the following conditions:
maximum counterpressure at the outlet valve. Take the pressure losses along the outlet line
to the injection point into account.
dosing medium with viscosity and density similar to those of water
flooded suction 0.5 m
fully deaerated dosing head
stroke length 100 %
three-phase 400 V motor.
Pump type
DMX 4-10
DMX 7-10
DMX 9-10
DMX 12-10
DMX 17-4
DMX 25-3
*1
DMX 7.2-16
DMX 8-10
DMX 14-10
DMX 18-10
DMX 26-10
DMX 39-4
DMX 60-3
*1
DMX 13.7-16
DMX 16-10
DMX 16-12
DMX 27-10
DMX 27-12
DMX 35-10
DMX 50-10
DMX 75-4
DMX 115-3
*1
Operating the pump at a counterpressure of 16 bar will reduce the life of the dosing dia-
phragm.
Stroke volume and stroke rate
The values in the table below apply to the following conditions:
Maximum dosing flow
50 Hz
60 Hz
[l/h]
[l/h]
[US gph]
4
5
1.3
7
8
2.1
9
11
2.9
12
14
3.7
17
20
5.3
27
32
8.5
7.2
9
2.3
8
10
2.6
14
17
4.5
18
22
5.8
26
31
8.2
39
47
12.4
60
72
19.0
13.7
16
4.3
16
19
5.0
15.7
19
5.0
27
32
8.5
26.8
32
8.5
35
42
11.1
50
60
15.8
75
90
23.8
115
138
36.5
Maximum counterpressure
[bar]
[psi]
10
145
10
145
10
145
10
145
4
58
3
43
16
232
10
145
10
145
10
145
10
145
4
58
3
43
16
232
10
145
12
174
10
145
12
174
10
145
10
145
4
58
3
43
DMX 221 | | 40