Translation of the Original Operating Instructions
4. Scope of delivery
The scope of the delivery of this product includes:
Pump with electronic control, integrated filter, a connection cord and one operat-
ing manual.
Please verify that the scope of delivery is complete. Depending on the purpose of
the application, additional accessories may be necessary (please refer to the
chapters titled "Installation" and "How to order spare parts").
If possible, keep the packing until the warranty period has expired. Please dis-
pose of the packing materials in an environmental-friendly manner.
5. Installation
5.1.
General installation information
During the entire process of installation, the device must not be con-
nected to the electrical mains.
The pump should be installed in a dry place with an ambient tempera-
ture not to fall below 5 °C. The pump and the entire connection system
have to be protected from frost and other climatic influences.
When installing the device, please make sure that the motor is suffi-
ciently ventilated.
All connection lines have to be perfectly tight since leaking lines may affect the
performance of the pump and cause considerable damage. Therefore, please
cause damage. When laying the connection pipes, you should make sure that
the pump is not exposed to any form of weight, vibration or tension. Moreover,
the connection lines must not contain any kinks or an adverse slope.
Please observe the illustrations, too, which are contained as an attachment at the
end of the present operating instructions. The numeric and other details included
in brackets below refer to these illustrations.
use Teflon tape to seal the
contact surfaces between the
Fig.1
threaded sections of the lines
and the connection with the
pump (Fig.1). This use of seal-
ing material such as Teflon
tape is the only way to ensure
an airtight assembly.
Avoid when tightening screw
excessive force that may
4
21