ALC 01
This alarms triggers if the con-
trol system does not receive any
impulse from the group flow-
meter when coffee is being dis-
pensed from group 1.
PROBABLE CAUSES ARE:
• Flowmeter is locked
• Flowmeter connecting cable is
not properly connected
CONSEQUENCES:
• Anomaly is signaled. Dispen-
sing will be locked depending on
the time that has been set du-
ring dose set up
ALC 02
This alarm concerns group 2
ALC 03
This alarm concerns group 3
ALT 01
This alarm triggers three minu-
tes after pressing the manual
free doses button of group 1 wi-
thout switching it off.
PROBABLE CAUSES ARE:
• User's negligence
CONSEQUENCES:
• Anomaly is signaled and dis-
pensing locked.
To cancel the alarm, press the
CANC button below the display
ALT 02
This alarm concerns group 2
ALT 03
This alarm concerns group 3
ALM 01
This alarms triggers when the
pre-set number of cycles of
group 1 solenoid valve is reached.
To cancel the alarm, press the
CANC button below the display
ALM 02
This alarm concerns the cycle
counter of group 2 solenoid valve
ALM 03
This alarm concerns the cycle
counter of group 3 solenoid valve
ALM 05
This alarm concerns the cycle
counter of the pump
ALM 06
This alarm concerns the cycle
counter of the auto-fill solenoid
valve
ALM 07
This alarm concerns the cycle
counter of the tea solenoid valve
ALM 08
This alarm concerns the cycle
counter of the MCS solenoid valve