P R ECAU T I O N S ( C O N T I N U E D )
• The FIX Device is intended to be stored and used at room
temperature. Do not store FIX Device in the sun or on a hot surface.
High temperatures may be damaging. The device should be
operated, transported and stored in the manner specified in this
manual. Failure to use and maintain the device in accordance with the
instructions outlined in this manual will void the warranty.
• Only use the Micro USB Cable provided with your FIX Device.
The NuFACE FIX® Device is intended for cosmetic use on the face
as described. Any consequence resulting from misuse, application
to other parts of the body or face, connection to improper voltage
sources, dirty spheres, expired or non-NuFACE conductive alternative,
or any other improper application is neither the responsibility of
NuFACE nor its affiliates.
B E FO R E U S I N G YO U R D E V I C E
1) Remove your FIX Device and Micro USB cable from the box.
2) Connect your FIX Device to a USB outlet to begin charging, safely
away from any source of water, on a table or countertop. A single
short pulse will occur when the device is properly connected. The
white LED light will blink, showing that your FIX Device is charging. The
light will stay illuminated when device is fully charged.
Note: The FIX Device cannot be used while plugged in and will not
turn ON while charging.
3) Important: Charge your FIX Device for 4 hours before the first
use. The white LED light flashes to indicate that the beauty device
is charging. When charging is complete, the white light will It lights
up continuously.
4) Important: Test your skin to make sure you are not sensitive
to the NuFACE Microcurrent Activator. To do so, rub a dime-sized
amount of Microcurrent Activator on your forearm and leave for 15-30
minutes before washing it off. If an allergic reaction (rash, redness,
etc) develops, immediately contact NuFACE for recommendations on
alternative NuFACE formulas. You should not initiate treatment with
the FIX Device until your reaction to the Microcurrent Activator has
been resolved.
5) When your FIX Device is ON it will emit an energizing hum and the
white LEDs will illuminate.
Note: There is only one intensity level to the device.
6) Important: Always ensure that the two (2) spheres remain in
direct contact with the skin. Avoid pulling or stretching the skin
during treatment.
7) The FIX Device energizing hum will emit 3 rapid pulses during
treatment when the battery needs recharging.
Note: The FIX Device will NOT contract the muscles. The current is
soft, soothing, and mild when used correctly.
D E V I C E F E E D BAC K
3 Rapid Pulses
2 Long Pulses
1 Long Pulse
6
I N D I CAT E S
Low Battery. Need to charge device.
Device is charging.
Device is still attached to charger.
Disconnect in order to turn device ON.