• Use of solvents and cleaning agents based on halogenised hydrocar-
bons! Chemical reactions which may occur when using these sub-
stances could be explosive!
7. Use
• Use only solvent-resistant, antistatic, undamaged and technically flaw-
less air hoses with a permanent pressure resistance of minimum 10
bar, e.g. Art. No. 53090!
Ensure the following conditions:
• Use a compressed air connection G 1/4 male thread or a fitting SATA
connection nipple.
• Ensure minimum air volume (air consumption) and pressure setting
(recommended spray gun inlet pressure) according to chapter 2.
• Ensure clean compressed air, e.g. by installing a SATA filter 100, Art.
No. 148247, outside the spray booth or a SATA filter 484, Art. No.
92320 inside the spray booth
• Use an air hose with minimum 6 mm inner diameter (see warnings),
e.g. Art. No. 53090.
13. Check if all screws [2-1], [2-2], [2-3], [2-4] and [2-5] have been
tightened firmly. Tighten fluid tip [2-1] firmly by hand (12 Nm) accord-
ing to [7-4]. Check if locking screw [2-5] has been firmly tightened
according to [10-1]. Tighten, if necessary.
14. Adjust air cap: vertical spray fan [2-6], horizontal spray fan [2-7].
3. With SATAminijet 1000 K RP: Connect the material hose of the tank
or pump to the spray gun material connection.
With SATAminijet 1000 H RP: Connect the suction cup, e.g. SATA
RPS 0.3 l cup w/ RPS adapter, to the material connection [1-3]. When
using a RPS 0.3 l suction cup set, first locate the plastic insert into
the neck of the RPS cup lid from above before pressing in the pick-up
Warning! Risk of explosion!
Warning! Risk of explosion!
Notice!
EN
105