Descargar Imprimir esta página

Trouble-Shooting - SATA minijet 1000 K RP Instrucciones De Servicio

Ocultar thumbs Ver también para minijet 1000 K RP:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 125
Operating instructions SATAminijet 1000 K RP, SATAminijet 1000 H RP
EN
EN
9.5. Replacing the seal (air side)
• Disconnect spray gun from the compressed air circuit!
Steps: [10-4], [10-5], [10-6], [10-7], [10-6], [10-5] and [10-4]
Replacing the self-adjusting seal [10-7] is required when air leaks from
under the trigger.
1. After disassembly, please check air piston rod [10-8] and clean it, if
required. If damaged (e.g. if scratched or bent), replace it and grease
with SATA high performance spray gun grease (Art. No. 48173) and
insert. Please observe correct order of installation!
After installation, please adjust material flow according to chapter 7.2.
• Check if locking screw has been firmly tightened! Air micrometer could
shoot out from the spray gun uncontrolled!
9.6. Replacing the spindle of round/flat spray con-
trol
The spindle has to be replaced when air leaks from the spray control or
when the spray control does not work.

10. Trouble-shooting

Malfunction
Fluttering/Spitting
spray fan or air bub-
bles appearing in the
suction cup
110
110
All manuals and user guides at all-guides.com
Warning!
Warning!
Steps: [11-1], [11-2], [11-3], [11-2], [11-1]
Cause
Fluid tip has not been
properly tightened
Air distribution ring is
damaged or clogged.
Corrective Action
Tighten fluid tip [2-1]
with universal spanner
[7-4]
Replace air distribution
ring which will be dam-
aged during extraction

Publicidad

loading

Este manual también es adecuado para:

Minijet 1000 h rp