Self-cleaning brazier cleaning
The thermo stove requires simple and careful cleaning in order to always guarantee efficient performance
and regular operation.
If your thermo stove is equipped with a self-cleaning brazier, do not remove it during cleaning. The brazier
must remain fixed and be cleaned with an ash
vacuum cleaner.
Clean the brazier from the ash and any rest with the
appropriate tool. They could obstruct the air passages.
If the pellet in the tank is exhausted, there might be
a residual unburnt pellets in the brazier. If the pellet
in the tank is exhausted, there might be a residual
unburnt pellets in the brazier. It's also important to
clean the ash accumulated inside of the combustion
room around the brazier. The frequency of this
operation depends on the use of the thermostove.
The decreased or absent cleaning can cause misfire and cause damage to the
thermostove and the environment (possible emissions of soot and unburned). Do not
pour the pellets may be present in the brazier to misfire.
Cleaning exchanger - thermostove off
Fouling act as insulation and the thicker they are,
the lower the heat that is transmitted to the water
and to the structure generally. Therefore very
important to perform the cleaning of the tube
bundle, said exchanger also, to prevent the fouling
of the same and prevent clogging and jamming of
the cleaning device. Pull and push quickly for 5-6
times the lever so that the springs can remove the
soot deposited on the pipes.
Cleaning the steel flame-shell
Every 2-3 days it is important to remove the steel
flame-shell in order to clean it and remove the dirty
that may fall during the cleaning of the exchange
pipes.