Method
1. Measure and draw the chimney connection (taking any floor plate thickness into consideration).
2. Chisel out (drill) the hole in the wall
3. Brick in the wall lining
4. Connect stove with the flue tube to the chimney.
FLOOR PROTECTION
For flammable floor surfaces (wood, carpet, etc.) a glass, steel plate or ceramic underlay is
required.SAFETY DISTANCES (measured from the outside of the stove)
From non-combustible objects
A > 400 mm, B > 100 mm, C > 100 mm
From combustible objects and to load-bearing walls in reinforced concrete
A > 800 mm, B > 200 mm, C > 200 mm
ELECTRICAL CONNECTION
The stove is supplied with an approx. 2 m long connecting cable with a plug. The cable must be
connected to a 230 V, 50 Hz electrical supply.
The average electric power consumption is approx. 100 watts during heating.
During the automatic ignition process (duration 10 minutes) approx. 350 watts.
The connection cable must be laid so that any contact with hot or sharp-edged external surfaces on
the stove is avoided.