SAFETY
POWER FAILURE
After the power failure, the display will be show E7. If short power failure, you can manually go back
to „Stabilization". Clear the E7 by „okay button", restarting the stove and pressing „fire button" for
3 seconds
During power failure a small amount of smoke may be emitted. This does not last for
more than three to five minutes and does not present safety risks.
POWER INPUT SOCKET (contains the main fuse)).
ELECTRIC EXCESS-CURRENT SHUT OFF
The device is protected against excess current by a main fuse (on the rear of the device)
The following is a list of main components and their functions:
IGNITER
The STOVE comes equipped with an automatic igniter for lighting the fuel when the stove is in
feeding and lighting mode.
VACCUM SWITCH
The STOVE has s vacuum switch located behind the left door, fastened to the base.
If a low pressure is created in the firebox by a leak, opening the front door, a blocked flue, or
unsealed ash drawer (some models), the vacuum switch will sense it and cause the stove to go into
a shutdown mode by showing E5.
AUGER AND AUGER MOTOR
The 2 RPM auger motor turns the auger, lifting pellets up the auger tube.
The pellets are then dropped down a tube and into the firepot.
The auger motor is controlled by the control board.
PROTECT TEMPERATURE SENSOR TO AVOID OVERHEATING
A safety temperature switch switches the stove off automatically if it overheats, after the stove has
cooled down. Meanwhile it shows E6.
Whether the heating operation is continued or not depends on the remaining embers in the fire pan.
After you remove the Error Code by „Okay button", If re-ignition does not occur when the fuel supply
recommences, then the out of operation program (cleaning , lag phase) is carried out.
According to the pre-set mode the stove must be re-started.
CAUTION:
If overheating has occurred then maintenance or cleaning work must be carried out.
EXHAUSTED TEMPERATURE SENSOR FUNCTION AS LOW TEMPERATURE SWITCH OFF
If the stove cools down below a minimum temperature the stove will switch off. This switch off can
also occur if pre-heating is too slow.
EN
27
Version: 11
08.11.2022