system) allow water to flow for at least
30 seconds to ensure that the system is
primed.
• At this point, it is safe to turn the switch
clockwise into operating mode.
3) General Use
During general use, the module is already
primed, and it is not necessary to prime
the system. To start the module, follow
these steps:
• Ensure that filtered water is supplied to
the module.
• From the off position, turn the power
switch clockwise to place it into
operating mode.
• At this point, the elements will begin
to heat. When each heat zone reaches
set temperature, the module is ready for
use.
Total Dissolved Solids (All Equipment)
Total Hardness (Steam Only)
Total Hardness (Espresso and Pour-Over)
pH (All Equipment)
N.B.: For more detailed information about water quality, please visit www.modbar.com/
support.
4) Water Quality
Water
quality
the proper function of your Modbar
equipment. Improper water filtration can
lead to serious problems with both your
equipment and the quality of the coffee
produced. At a minimum, the following
water standards need to be met.
Water specifications table
90-150 ppm
Less than 3 gpg
Less than 5 gpg
6.5-7.5
is
very
important
to
13