Descargar Imprimir esta página

Important; Technical Specifications - Emos P5607 Manual De Instrucciones

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 106
GB | Thermostat
The P5607 thermostat is designed for controlling heating and air-condi-
tioning systems.

Important

• Before the first use, make sure to carefully read the operating manual
for the thermostat, as well as the manual for the boiler or air-condi-
tioning equipment.
• Turn off power before installing the thermostat!
• Installation should be carried out by a qualified professional!
• Abide by prescribed standards during installation.

Technical specifications:

Switched load: max. 230 V AC; 8 A for resistive load; 2 A for inductive
load
Temperature measurement: 0 °C to 40 °C with 0.1 °C resolution; accuracy
±1 °C at 20 °C
Temperature setting: 5 °C to 35 °C in 0.5 °C increments
Differential setting: 0.2 °C to 2 °C, in 0.1 °C increments
Power supply: 2× 1.5 V AAA batteries (LR03)
Accessories: 2 screws, 2 wall plugs
Dimensions and weight: 26 × 120 × 78 mm; 126 g
Description of Control Elements (fig. 1)
1 – select and edit programme
2 – adjust value
Screen Description (fig. 2)
1 – batteries low
2 – operating mode
3 – selected programme
4 – time
5 – days
6 – set temperature
INSTALLATION
Attention:
Before changing the thermostat, disconnect the heating/air-conditioning
system from the main power in your flat. This will prevent potential injury
by electric current.
Thermostat Placement
Thermostat placement significantly affects its functioning. Place it in a
room where members of the family spend most of their time. Choose a
spot preferably on an inside wall where air circulates freely and there is no
3 – thermostat settings
4 – time and date settings
7 – cooling mode
8 – heating mode
9 – room temperature
10 – HOLD mode
11 – manual mode
4

Publicidad

loading