Use the + and – buttons to adjust the temperature value by -3 to +3 °C
(0.5 °C resolution).
Confirm by pressing
Example: The thermostat shows room temperature of 22 °C; setting calibra-
tion to +1 °C will cause the thermostat to display 23 °C instead.
Temperature Differential Setting
The temperature differential (hysteresis) is the difference in temperature
required for switching the system on and off. If for example you set the
temperature in heating mode to 20 °C and differential to 0.2 °C, the ther-
mostat activates heating as soon as room temperature drops to 19.8 °C and
switches heating off when temperature reaches 20.2 °C.
Press and hold the
displayed. Press
diFF will appear on the screen and the temperature value will start flashing.
Use the + and – buttons to adjust temperature differential to 0.2 to +2 °C
(0.1 °C resolution).
Confirm by pressing
Short-Term Manual Change of Temperature
When in standard operating mode, where temperature is controlled by the
selected programme, it is possible to make a short-term change to the
current temperature setting.
Use the + and – buttons to set the new temperature and confirm with
The PRG icon will be replaced with a hand icon
until the next scheduled temperature change will be flashing.
Upon the next scheduled temperature change, the hand icon
disappear and the temperature will change according to the programme.
The manual change can also be overridden and ended prematurely using
the
button.
Long-Term Manual Change of Temperature (HOLD Mode)
When in standard operating mode, where temperature is controlled by
the selected programme, it is possible to make a long-term change to the
current temperature setting.
Use the + and – buttons to set the new temperature and confirm with
The
icon will be displayed and temperature will be flashing. You can again
use the + and – buttons to change the temperature and confirm with
The set temperature will be maintained until HOLD mode is cancelled.
Any programmed temperature change will not be carried out.
In this mode, you can use the + and – buttons to set a new temperature
and confirm with
.
To end HOLD mode, press the
.
button for 5 seconds. The SYSTEM table will be
twice.
.