page 6
AELR MODULE REPLACEMENT
With the unit oriented as shown
1
below, flex the left PCB guide for the
charger board outward to release and
remove the left side of PCB first then
remove the charger board.
To replace the antenna, disconnect
4
antenna from the AELR module and
then replace (antenna and battery
plate will come preinstalled).
CORTEZ
MAINTENANCE
Disconnect the battery connector
2
from charger board and remove
the battery (see page 5 for
additional information)
Make sure all wires are routed
5
properly as not to interfere with
proper assembly of the housing
onto the mounting plate. Then re-
assemble the unit (see also step
5, page 3).
LIFE SAFETY SOLUTIONS
TEL: 740-345-9631
www.holophane.com
To replace the AELR module,
3
disconnect the module from
charger board and replace
(antenna shown attached to AELR
module).