be used as a general guide only: some batteries maybe able
to handle a higher charge current. Check with the battery
manufacturer when charging batteries with small capacity.
Charge current
Battery capacity charging
Battery capacity maintaining
ENVIRONMENTAL CHARACTERISTICS
Operating Temperature: 0 to 45°C.
•
Storage Temperature: -25 to 85°C.
•
Operating Humidity Range: 0 to 90% RH.
•
Cooling: passive / natural.
TECHNICAL SPECIFICATIONS
Part number
Type
Approvals
Input voltage range
Input frequency
Max output voltage
Charging current
Housing material
Size (LxWxH) in mm
Weight in Kg
Ingress protection
CHARGING MODE
The Fulload F4 has 7 charging modes as indicated in the table
below. Some charging modes must restart the charger and re-
connect the battery.
Use the mode button to switch the mode to change the battery
2A (12V)
4A (6V or 12V)
6-40Ah
12-80Ah
All battery sizes
Fulload F4
Automatic - 8 stages
CE
220V-240Vac
50Hz
Various
4A(6V/12V), 2A(12V)
ABS
153x72x43
0.31Kg
IP60
type. Before choosing, first understand the differences between
each rechargeable battery mode.
Do not operate the charger before confirming whether the batte-
ry charging mode is suitable.
Mode
In standby mode, the charger does
not charge or power the battery. In
Standby
this mode, the energy saving function
is activated, and standby power is
obtained from the power outlet.
12V Normal
Used for 12V lead-acid batteries (WET,
Charging Voltage:
MF, DRY, Ca/Ca and FLOODED). When
14.4V (4A)
selected, the white LED will light up.
Used to charge 12V AGM, SLA and GEL
12V AGM
batteries or to charge 12V batteries in
Charging Voltage:
winter mode. When selected, the white
14.8V (4A)
LED will light up.
Used to charge 12V lead-acid batteries
12V Normal
(WET, MF, DRY, Ca/Ca and FLOODED)
Charging Voltage:
with low current 2A. When selected, the
14.4V (2A)
white LED will light up.
Used to charge 12V AGM, GEL and SLA
12V AGM
batteries with low current 2A, or charge
Charging Voltage:
the 12V battery in winter mode, the
14.8V (2A)
white LED will light up when selected.
6V Normal
Used to charge 6V lead-acid battery,
Charging Voltage:
white LED will light up when selected.
7.2V (4A)
12V Lithium
Used to charge 12V lithium battery,
Charging Voltage:
white LED will light up when selected.
14.2V (4A)
12V REPAIR
Used for battery repair mode, used
Charging Voltage:
when the battery cannot be charged
15V (2A)
normally.
3
Explanation