Descargar Imprimir esta página

Stanley AV 5 Manual De Instrucciones Y Servicio página 6

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 132
ENGLISH
1.7 NOISE HAZARDS
Exposure to high noise levels can cause permanent, disabling hearing loss and other problems, such as tinnitus
(ringing, buzzing, whistling or humming in the ears). Therefore, risk assessment and the implementation of appro-
priate controls for these hazards are essential.
Appropriate controls to reduce the risk may include actions such as damping materials to prevent workpieces from
"ringing".
Use hearing protection in accordance with employer's instructions and as required by occupational health and
safety regulations.
Operate and maintain the tool as recommended in the instruction manual, to prevent an unnecessary increase in
the noise level.
1.8 VIBRATION HAZARDS
Exposure to vibration can cause disabling damage to the nerves and blood supply of the hands and arms.
Wear warm clothing when working in cold conditions and keep your hands warm and dry.
If you experience numbness, tingling, pain or whitening of the skin in your fi ngers or hands, stop using the tool, tell
your employer and consult a physician.
Where possible Support the weight of the tool in a stand, tensioner or balancer, because a lighter grip can then be
used to support the tool.
1.9 ADDITIONAL SAFETY INSTRUCTIONS FOR HYDRAULIC POWER TOOLS
The operating hydraulic supply must not exceed 550 bar (8000 PSI).
Oil under pressure can cause severe injury.
Do not fi t fl exible hydraulic hoses rated at less than 700 bar (10,000 PSI) working pressure at a fl ow rate of 2.73 l/min
(200 in 3/min).
Never leave operating tool unattended. Disconnect hydraulic hose and electrical cable from the pump unit when
tool is not in use, before changing accessories or when making repairs.
Whipping hoses can cause severe injury. Always check for damaged or loose hoses and fi ttings.
Prior to use, inspect hydraulic hoses for damage, all hydraulic connections must be clean, fully engaged and tight
before operation. Do not drop heavy objects on hoses. A sharp impact may cause internal damage and lead to
premature hose failure.
Whenever universal twist couplings (claw couplings) are used, lock pins shall be installed and whipcheck safety
cables shall be used to safeguard against possible hose-to-tool or hose-to-hose connection failure.
DO NOT lift the placing tool by the hose or electrical cable. Always use the placing tool handle.
DO NOT pull or move the hydraulic pump unit using the hoses. Always use the pump unit handle or roll cage.
Keep dirt and foreign matter out of the hydraulic system of the tool as this will cause the tool to malfunction.
Use only clean oil and fi lling equipment.
Only recommended hydraulic fl uids may be used.
Power units require a free fl ow of air for cooling purposes and should therefore be positioned in a well ventilated
area free from hazardous fumes.
Maximum temperature of the hydraulic fl uid at the inlet is 110°C (230°F).
STANLEY Engineered Fastening policy is one of continuous product development and improvement and
we reserve the right to change the specifi cation of any product without prior notice.
ORIGINAL INSTRUCTION
5

Publicidad

loading

Este manual también es adecuado para:

73425-02000