3.1 PRINCIPAL OF OPERATION
IMPORTANT - READ THE SAFETY RULES ON PAGES 4 - 6 AND THE PUMP UNIT INSTRUCTION MANUAL CAREFULLY
BEFORE PUTTING INTO SERVICE.
When both hoses and control cable are connected to the Avdel
/ Enerpac
hydraulic pump unit, the pull
®
®
and return cycles of the tool are controlled by depressing and releasing the trigger located in the handle.
When the switch is depressed the solenoid valve, located in the hydraulic pump unit, is energised and
directs the pressurised oil fl ow to the pull side of the piston in the placing tool. This also allows the oil in
the return side of the placing tool to return to the reservoir.
During the pull cycles the piston/collet assembly moves towards the rear of the tool allowing the O-ring
type cushion to push the follower and jaws forward. If a fastener pin has been inserted in the nose assem-
bly, the jaw set will clamp onto the pintail and assembly will commence.
For Avbolt
and Avdelok
the cycle of installation will fi rst clamp the joint to be fastened and then as the
®
®
anvil continues to move forward the collar will be swaged into the locking grooves of the pin. At the end
of the swaging cycle the anvil will come up against the joint and as movement continues the pintail will
be broken off.
The trigger switch should be released immediately after pin break occurs. Releasing the trigger switch will
cause the solenoid to de-energise and reverse the fl ow of pressurised oil.
If the trigger is not released, the placing tool piston will continue to move towards the rear of the tool until it reaches
the end of its stroke. The pressure in the pull side will then increase until a preset 'High Pressure' value is achieved at
the pump. At this point the solenoid valve will automatically de-energise and reverse the fl ow of pressurised oil to the
return side of the placing tool.
In either case, pressurised oil will now fl ow into the return side of the placing tool, with the oil in the pull side returning
to the reservoir.
The forward movement of the piston/collet assembly will eject the installed fastener from the anvil.
At the point of releasing the trigger or when the 'High Pressure' value is achieved, the solenoid valve will de-energise
and activate a preset 'Return Timer' . This controls the time that the pump motor will continue run before switching to
the idle mode. The timer can be manually set between 5 and 20 seconds to ensure that the placing tool piston always
fully returns to the forward position (refer to pump manual 07900-01030, pages 10 and 13).
When the piston returns to the fully forward position, the pressure will increase to preset low pressure value - c200bar.
The pump motor will continue to run until the Return Timer has expired. After this time period the motor will stop auto-
matically and valve will switch to the idle position. The solenoid valve will then automatically cycle to release pressuris-
ed oil to the reservoir from both the pull and return side of the placing tool.
This keeps the installation tool in the forward position. No pressure will be present in the hydraulic system at this point.
The hydraulic pump unit will automatically start up on depression of the tool trigger switch.