7. Also push the extraction hose onto the wall mount bracket (item 37)
and connect it to spiral pipe 1 (item 27). Then fix the hose ends with two
hose clamps.
8. Now attach the pull chain (item 35) to the cantilever arm.
NOTE
Only for extraction arms in rigid metal tube version. Shorten the rear tube
section to 900 mm.
NOTE
For example, a wire feed unit can be mounted for carrying in the hitch
under the cantilever arm.
ATTENTION
Note that the first cantilever arm has a maximum weight of 50 kg and
the second cantilever arm has
10 kg, which cannot be exceeded.