English
By controlling the receiver alone, the towel warmer can be
switched on manually and temporarily. With a quick press of the
button: Light 1 turns on. Then, with subsequent presses, light 1
will switch from on (relay on) to off (relay off) in sequence. This
manual command will be cancelled on the next order received.
If there is no remote control paired, the surface limitation
function is not active. The duration of forced mode is 1 hour
max. The appliance is designed to be safe both during normal
use and under abnormal conditions, whatever the state and
setting of the surface limitation function.
12.
Description of RF Receiver and
Remote Control
Remote Control Buttons
1) Battery compartment
2) Mode =>Selection of the operating
modes
3) + and - buttons used to set
temperatures, date, time and weekly
program
4) OK => Save settings
5) Boost button
6) Temperature selection knob
7) LCD display
Description of display indicators
Modes of operation
Auto mode
Comfort mode
Eco mode
Frost protection mode
date and time setting mode
Programming mode
Settings
8
1
2
3
4
5
6
7
days of the week
(1=Monday...7= Sunday)
(1) Current ambient temperature /
surface temperature limitation
(2) Energy consumption
(3) Surface temperature
limitation/current ambient
temperature
(4) Boost light indicator
(5) Open window detection
occupation indicator
9
10
(6) Keypad locked
11
(7) Days of the week
12
13
(8) Operating modes
(9) Heating indicator
(10) Pilot wire indicator (France
only)
(11) Low battery indicator
(12) Radio transmission indicator
(13) Min/max value indicator
13. Heating with ambient temperature
setpoint or surface temperature
setpoint
This towel warmer allows to choose two operating modes:
Heating with "Ambient temperature setpoint": In this
mode, ambient temperature control is implemented with
a limitation of the product surface temperature.
Heating with "Surface temperature setpoint": In this
mode, surface temperature control is implemented with
a limitation of ambient temperature.
The default mode is Heating with ambient temperature setpoint.
Mode setting:
Press the Mode key on the
remote control for 5 sec
The information screen is
displayed
Shortly press the Mode key
on the remote control twice
The information screen is
displayed
COnF upon first pressure
USEr upon second pressure
Confirm by pressing OK key
for 10 sec
The information screen is
displayed
Press
and
the same time for 10 seconds
The Pro screen (advanced
installer
settings)
displayed
- 26 -
Switching on/
standby mode
Connection -
manual heating
start
keys at
= Advanced installer
settings
is
Code 1910000000358 - nv02

Publicidad

loading

Este manual también es adecuado para:

Tessuto electric el.4x1800