74
0x004A
0
Display unit
75
0x004B
0
Output filter
76
0x004C
0
Display-Mode
Display-brightness
78
0x004E
0
Display rotation
79
0x004F
0
Language selection
81
0x0051
0
86
0x0056
0
Drop-Off valve (SIO-Mode & manual mode)
1
Us X11 (Pin 1 and Pin 2)
87
0x0057
2
Us X12 (Pin 1 and Pin 2)
Ua X11 (Pin 3 and Pin 5)
1
88
0x0058
2
Ua X12 (Pin 3 and Pin 5)
89
0x0059
0
SP2 selection/displayed vacuum value
ISDU X11 X12 (IOL-Devices external connectors)
10200
0x27D8
0
ISDU: Index
10201
0x27D9
0
ISDU: Subindex
10202
0x27DA
0
ISDU: RW
10203
0x27DB
0
ISDU: Length
ISDU: Data
10204
0x27DC
0
10205
0x27DD
0
ISDU: Trigger
10206
0x27DE
0
ISDU: Status
10207
0x27DF
0
ISDU: Extended error code
10208
0x27E0
0
ISDU: Valve select
1
byte
0-3
rw
2
bytes
0-999
rw
1
byte
0-2
rw
1
byte
0-100
rw
1
byte
0-1
rw
1
byte
0-4
rw
1
byte
0-7
rw
1
byte
0-1
rw
1
byte
0-1
rw
1
byte
0-2
rw
1
byte
0-2
rw
1
byte
0-7
rw
2
bytes
0-16353
rw
1
byte
0-255
rw
1
byte
0-1
rw
1
byte
0-64
rw
64
bytes
je 0-255
rw
1
byte
0-1
rw
1
byte
-
ro
1
byte
-
ro
1
byte
1-2
rw
0 = mbar,
1 = kPa,
0
2 = inHg,
3 = psi
10
Unit: 1ms
0 = vacuum,
1 = menu,
0
2 = eco
(Change after 60s without display-touch)
100
Unit: 1%
0 = standard,
0
1 = 180° rotated
0 = english,
1 = german,
0
2 = french,
3 = spanish,
4 = italian
0 = GCP,
1 = X11,
2 = X12,
3 = GCP & X11,
7
4 = GCP & X12,
5 = X11 & X12,
6 = GCP & X11 & X12
7 = Automatic
1
0 = off,
1 = on
1
0 = off,
2
1 = on,
2 = linked to SIO-Signal "drop-off"/controlled by process data (IO-Link)
2
(Ua always on if LQE connected, and always off if VSi connected)
0 = GCP,
1 = X11,
2 = X12,
3 = GCP & X11,
7
4 = GCP & X12,
5 = X11 & X12,
6 = GCP & X11 & X12
7 = Automatic
0
ISDU-Index
0
ISDU-Subindex
0 = read,
0
1 = write
0
Length of ISDU
0
64-Byte Data
0
1 = Start ISDU process
0 = No ISDU process started,
1 = ISDU process ongoing,
-
2 = ISDU process finished successfully,
3 = ISDU process terminated with errors (see extended error code)
-
Extended error code IO-Link specification
0 = X11,
1
1 = X12