Production Setup P3
222
0x00DE
0
Switchpoint 1 (SP1)
224
0x00E0
0
Switchpoint 2 (SP2)
225
0x00E1
0
Resetpoint 2 (rP2)
226
0x00E2
0
Duration automatic drop-off
227
0x00E3
0
Permissible evacuation time
228
0x00E4
0
Permissible leakage rate
231
0x00E7
0
Max. allowed power
239
0x00EF
0
Profile name
Observation
Monitoring
1
System vacuum live
System vacuum min
64
0x0040
2
3
System vacuum max
1
Primary supply voltage live
66
0x0042
2
Primary supply voltage min
3
Primary supply voltage max
1
Auxiliary supply voltage live
67
0x0043
2
Auxiliary supply voltage min
3
Auxiliary supply voltage max
1
Temperature live
68
0x0044
2
Temperature min
Temperature max
3
Communication mode
564
0x0234
0
Diagnosis
Device Status
36
0x0024
0
Device status
Detailed device status
37
0x0025
0
130
0x0082
0
Active errors
999 > SP1
2
bytes
rw
>= SP2+ 50
rP1 > SP2
2
bytes
rw
> rP2
SP2 > rP2
2
bytes
rw
>= 10
2
bytes
10-9999
rw
2
bytes
0-9999
rw
2
bytes
0-9999
rw
1
byte
10-100
rw
0...16
bytes
-
rw
2
bytes
ro
2
bytes
-
ro
2
bytes
ro
2
bytes
ro
2
bytes
-
ro
2
bytes
ro
2
bytes
ro
2
bytes
-
ro
2
bytes
ro
2
bytes
ro
2
bytes
-
ro
2
bytes
ro
1
byte
-
ro
1
byte
-
ro
96
bytes
-
ro
2
bytes
-
ro
800
Unit: 1mbar
550
Unit: 1mbar
540
Unit: 1mbar
200
Unit: 1ms
Unit: 1ms,
2000
no evacuation time warning if set to 0
Unit: 1mL/min,
2000
no leakage rate warning if set to 0
100
Unit: %
***
Name of profile
Unit: 1mbar
-
Unit: 1mbar
Unit: 1mbar
Unit: 0.1V
-
Unit: 0.1V
Unit: 0.1V
Unit: 0.1V
-
Unit: 0.1V
Unit: 0.1V
Unit: 0.1°C
-
Unit: 0.1°C
Unit: 0.1°C
0x00 = SIO mode
-
0x11 = IO-Link
0 = Device is operating properly
1 = Maintenance required
-
2 = Out of Spec
3 = unused
4 = Failure
Information about currently pending events (Event-List)
Byte 0 = Type of Event 1
-
Byte 1...2 = ID of Event 1
Byte 3 = Type of Event 2
Byte 4...5 = ID of Event 2 etc.
Bit 0 = Internal error: data corruption
Bit 1 = Temperature overrun
Bit 2 = Primary voltage too low
Bit 3 = Primary voltage too high
Bit 4 = Auxiliary voltage too low
Bit 5 = Auxiliary voltage too high
-
Bit 6 = Short circuit at OUT2
Bit 7 = Short circuit at OUT3
Bit 8...9 = reserved
Bit 10 = Sensor calibration failed
Bit 11 = Pump not working properly
Bit 12...14= reserved
Bit 15 = IO-Link communication interruption