Condition Monitoring [CM]
146
0x0092
0
Condition monitoring
Counters
140
0x008C
0
Vacuum on counter
Condition monitoring counter
142
0x008E
0
143
0x008F
0
Vacuum on counter
145
0x0091
0
Condition monitoring counter
Timing
Total cycle time of last cycle GCP
1
166
0x00A6
2
Total cycle time of last cycle X11
Total cycle time of last cycle X12
3
Evacuation time t0 of last suction-cycle GCP
1
148
0x0094
2
Evacuation time t0 of last suction-cycle X11
3
Evacuation time t0 of last suction-cycle X12
Evacuation time t1 of last suction-cycle GCP
1
149
0x0095
2
Evacuation time t1 of last suction-cycle X11
3
Evacuation time t1 of last suction-cycle X12
1
Holding time t2 of last suction-cycle GCP
170
0x00AA
2
Holding time t2 of last suction-cycle X11
3
Holding time t2 of last suction-cycle X12
1
Drop-off time t3 of last suction-cycle GCP
171
0x00AB
2
Drop-off time t3 of last suction-cycle X11
3
Drop-off time t3 of last suction-cycle X12
167
0x00A7
0
Pump-on total time
Power-on total time
168
0x00A8
0
Energy Monitoring [EM]
1
Energy consumption of last suction-cycle GCP
Energy consumption of last suction-cycle X11
157
0x009D
2
3
Energy consumption of last suction-cycle X12
Predictive Maintenance [PM]
160
0x00A0
0
Leakage rate
Free-Flow vacuum
161
0x00A1
0
Max reached vacuum
164
0x00A4
0
162
0x00A2
0
Quality
163
0x00A3
0
Performance
2
bytes
-
ro
4
bytes
-
ro
4
bytes
-
ro
4
bytes
-
ro
4
bytes
-
ro
4
bytes
-
ro
4
bytes
-
ro
4
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
4
bytes
-
ro
4
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
2
bytes
-
ro
1
byte
-
ro
1
byte
-
ro
Bit 0 = reserved
Bit 1 = Evacuation time above limit
Bit 2 = Leakage rate above limit
Bit 3 = SP1 not reached in suction cycle
Bit 4 = Free Flow Vacuum over SP2
-
Bit 5 = Primary Voltage US out of operating range
Bit 6 = Auxiliary voltage UA out of operating range
Bit 7 =Temperature out of operating range
Bit 8 = Vacuum sank under rP2 during suction
Bit 9...15 = reserved
-
Counter for Vacuum on (non-erasable, saved every 20 mins)
-
Counter for condition monitorings (non-erasable, every all 20 mins)
-
Counter for Vacuum on (erasable, saved every 20 mins)
-
Counter for condition monitorings (erasable, saved every 20 mins)
-
Unit: 1ms
-
Unit: 1ms
-
Unit: 1ms
-
Unit: 1ms
-
Unit: 1ms
-
Unit: 1ms
-
Unit: 1ms
-
Unit: 1ms
-
Unit: 1ms
-
Unit: 1ms
-
Unit: 1ms
-
Unit: 1ms
-
Unit: 1ms
-
Unit: 1ms
-
Unit: 1ms
-
Unit: 1min (saved every 20 mins)
-
Unit: 1min (saved every 20 mins)
-
Unit: 1Ws
-
Unit: 1Ws
-
Unit: 1Ws
-
Unit: 1mL/min
-
Unit: 1mbar
-
Unit: 1mbar
-
Unit: 1%
-
Unit: 1%