Process Settings
275
0x0113
0
Active profile
Production Setup P0/Setup For SIO-Mode
Switchpoint 1 (SP1)
100
0x0064
0
Switchpoint 2 (SP2)
102
0x0066
0
Resetpoint 2 (rP2)
103
0x0067
0
106
0x006A
0
Duration automatic drop-off
Permissible evacuation time
107
0x006B
0
108
0x006C
0
Permissible leakage rate
111
0x006F
0
Max. allowed power
Profile name
119
0x0077
0
Production Setup P1
182
0x00B6
0
Switchpoint 1 (SP1)
184
0x00B8
0
Switchpoint 2 (SP2)
185
0x00B9
0
Resetpoint 2 (rP2)
186
0x00BA
0
Duration automatic drop-off
187
0x00BB
0
Permissable evacuation time
188
0x00BC
0
Permissable leakage rate
191
0x00BF
0
Max. allowed power
199
0x00C7
0
Profile name
Production Setup P2
202
0x00CA
0
Switchpoint 1 (SP1)
204
0x00CC
0
Switchpoint 2 (SP2)
205
0x00CD
0
Resetpoint 2 (rP2)
206
0x00CE
0
Duration automatic drop-off
207
0x00CF
0
Permissible evacuation time
208
0x00D0
0
Permissible leakage rate
211
0x00D3
0
Max. allowed power
219
0x00DB
0
Profile name
1
byte
0-3
rw
999 > SP1
2
bytes
rw
>= SP2+ 50
rP1 > SP2
2
bytes
rw
> rP2
SP2 > rP2
2
bytes
rw
>= 10
2
bytes
10-9999
rw
2
bytes
0-9999
rw
2
bytes
0-9999
rw
1
byte
10-100
rw
0...16
bytes
-
rw
999 > SP1
2
bytes
rw
>= SP2+ 50
rP1 > SP2
2
bytes
rw
> rP2
SP2 > rP2
2
bytes
rw
>= 10
2
bytes
10-9999
rw
2
bytes
0-9999
rw
2
bytes
0-9999
rw
1
byte
10-100
rw
0...16
bytes
-
rw
999 > SP1
2
bytes
rw
>= SP2+ 50
rP1 > SP2
2
bytes
rw
> rP2
SP2 > rP2
2
bytes
rw
>= 10
2
bytes
10-9999
rw
2
bytes
0-9999
rw
2
bytes
0-9999
rw
1
byte
10-100
rw
0...16
bytes
-
rw
0
Number of active profile
800
Unit: 1mbar
550
Unit: 1mbar
540
Unit: 1mbar
200
Unit: 1ms
Unit: 1ms,
2000
no evacuation time warning if set to 0
Unit: 1mL/min,
2000
no leakage rate warning if set to 0
100
Unit: %
***
Name of profile
800
Unit: 1mbar
550
Unit: 1mbar
540
Unit: 1mbar
200
Unit: 1ms
Unit: 1ms,
2000
no evacuation time warning if set to 0
Unit: 1mL/min,
2000
no leakage rate warning if set to 0
100
Unit: %
***
Name of profile
800
Unit: 1mbar
550
Unit: 1mbar
540
Unit: 1mbar
200
Unit: 1ms
Unit: 1ms,
2000
no evacuation time warning if set to 0
Unit: 1mL/min,
2000
no leakage rate warning if set to 0
100
Unit: %
***
Name of profile