4. PRE-OPERATION FOR STARTING
1. Install the hose connector.
Be sure to check that the packing is seated in its place and install the
hose connector to the port on the pump.
HOSE CONNECTOR
PACKING
HOSE COUPLING
HOSE CLAMP RING
2. Connect the suction hose.
Use commercially available hose, hose connector, and hose bands.
The suction hose must be of reinforced, noncollapsible construction.
Suction hose length should not be longer than necessary, as pump
performance is best when the pump is not far above the water level.
Self-priming time is also proportional to hose length.
The strainer that is provided with the pump should be attached to the
end of the suction hose with a band, as shown.
CAUTION:
Always install the strainer on the end of the suction hose before
pumping. The strainer will exclude debris that can cause clogging or
impeller damage.
HOSE CONNECTOR
STRAINER
SUCTION HOSE
HOSE BAND
HOSE BAND
10