7.
If something does not work
7.1.
Error indication at operation mode LEDs
Repair and maintenance is to be carried out exclusively by Klafs' service personnel or by
personnel expressly authorized by Klafs!
The following errors are indicated by simultaneous flashing of all LEDs.
No.
Display
1
Fast flashing.
2
Slow flashing.
3
Short flashing (0.1 sec On
0.9 sec. Off).
7.2.
Other possible errors
Error
The control
system cannot be
switched On.
The cabin light
does not turn On
Evaporator does
not heat.
PAGE 14
Error
Error safety temperature limiter (STL).
Error temperature sensor.
Error on one of the rotary control knobs of the control
system.
Cause
No mains voltage.
The main switch of the
control system is not
switched On.
Bulb defective.
No mains voltage.
Fuse SI100 cut out.
Acoustic signal on heater.
Water tank is empty.
Remedy
Check the FI-switch and the fuse in the mains
supply.
Switch On the main switch at the control
system.
Procedure:
Remove power from the control system.
Change the bulb.
.
Replace with a bulb of the same
wattage.
Check the FI-switch and the fuse in the mains
supply.
Change the fuse SI100 (1.25 AT) or inform
Klafs Service.
Fill water tank with water.
Softclima