8.2.
Service menus
Service menus marked with an asterisk * are not functional on the 21029 sauna
controller (changing these values will not have any effect on operation).
No.
Menu
03
SaunaP
90 °C
04 )*
Humidity sensor
05
Bathing time
06 )*
Humidity offset
07
Temperature offset
08
Output detection
09
Music
60 °C
11
Clear fault
12
Clear operating data
17
Preset time mode
18
Cabin temperature
19
Exhaust air
20
KEYGUARD
40 °C
21
Green Sauna
23
Fill the scent line
Input
0 = Disable SaunaP
UR
1 = Enable SaunaP
2 = Enable SaunaP
3 = Gas sauna heater control algorithm
C0/C1
01 hr, 03 hr, 04 hr, 06 hr, 12 hr, 18 hr
±10 g/m
±5 °C (limiter)
D
0 = not activated / 1 = activated 60 °C / 2 = activated 75 °C )*
0 = Automatic music / 1 = Music off / 2 = Music on
0 = Do not clear fault / 1 = Clear fault
0 = Do not clear operating data, 1 = Clear operating data
0 = Preset time mode off, 1 = Preset time mode on
0 = 100 °C / 40 °C not activated,
1 = 100 °C / 52 °C activated,
2 = 110 °C / 40 °C not activated,
3 = 110 °C / 52 °C activated
0 = electric cover flap, 2 = fan ignition angle -50 μs, 3 = fan ignition
angle -25 μs, 4 = fan ignition angle +25 μs, 5 = fan ignition angle +50
μs
0 = Disabled, 1 = Enabled,
2 = Door contact, 3 = CBC/remote without key switch
0 = disable, 1 = enabled,
2 = Green Sauna with fan run-on, 3 = Green Sauna without buttons,
4 = Green Sauna without buttons with fan run-on
0 = Do not fill the scent line, 1 = Fill the scent line
,
UR
FAI 3,
UR
FAI 4/FAI 5
UR
3
When using an under-bench heater, set the temperature
offset to +5 °C.
Page 27 / 104