8.2.
Service menus
Service menus marked with an asterisk * are not functional on the 21029 sauna
controller (changing these values will not have any effect on operation).
No.
Menu
35
Calibrate safety module
90 °C
36
Activate CM CO
37
max. fan speed
60 °C
38
lower CO
39
upper CO
40
Several
coloured lights
45
Select
lighting
40 °C
46
Select SUNSET
Input
Calibrating the heat-up phase for switching on via remote start, preset
time mode or the app.
D
D
Climate Manager
2
0
off
1
on
Set the maximum fan speed.
Default = 10
Can be set between 0 and 10.
limit
Control start of Climate Manager offset.
2
Default = 1
Can be set between 0 and 20 (20 equals 2000 ppm).
limit
Climate Manager maximum possible CO
2
Default = 20
Can be set between 8 and 50 (50 equals 5000 ppm).
synchronised
0
off
1
on
230
V
cabin
0-10 V Ext
Standard
0-10 at light output
on/off AG2
Sunset 0-10 V ext
Sunset RGB ext
PWM on <L+ L->
none
Only carry out this process when the cabin and the sauna
heater are cold. Otherwise, the measured values will be
distorted and the monitoring will not work correctly during
operation.
Carry out the calibration process, see page 33.
0-10 V AG1
on/off light output
Sunset 0-10 V AG1
Sunset RGB AG1
on/off AG1
value.
2
0-10 V AG2
on/off AG1
Sunset 0-10 V AG2
Sunset RGB AG2
on/off AG2
Page 30 / 104