8.2.
Service menus
Service menus marked with an asterisk * are not functional on the 21029 sauna
controller (changing these values will not have any effect on operation).
No.
Menu
34
Setting the sauna heater
type
90 °C
60 °C
40 °C
Input
Setting the sauna heater type for monitoring the heat-up phase for remote
start or preset time mode.
0
Increase of 5 Kelvin within 3 minutes (default),
Sauna heaters: Majus/SANARIUM M 6 - 12 kW,
Pluris/Pluris Softclima 4.5 - 9 kW,
Trumpf 3 - 9 kW,
Softclima 3 - 7.5 kW,
BONATHERM VS 6 - 12 kW, BONATHERM 6 - 15 kW, B 6 -
12 kW, SANARIUM B 6 - 12 kW,
Fero/Fero S 4.5 - 12 kW
1
Increase of 5 Kelvin within 2 minutes,
Sauna heaters: Majus 16 - 30 kW,
Pluris Softclima 12 kW,
Softclima 9 kW
2
Increase of 5 Kelvin within 5 minutes,
Sauna heaters: Pluris Softclima 3 kW, Fero/Fero S 3 - 3.3 kW
3
Not used
4
Not used
5
Individual heat-up curve. Calibration via service menu 35, see
page 33.