7.6
230 V fuse box with an RCD
The 230 V fuse box with RCD protects the 230 V circuit and is therefore fitted with a 25 A fuse. In addition,
an RCD is integrated that interrupts the current flow in the event of leakage currents and short circuits.
CAUTION
Risk of damaging the electrical system!
If the RCD is triggered (interruption of the current flow), the cause has to be identified.
● In this case, contact your authorised dealer or an authorised specialist workshop.
7.7
12 V fuse box with distribution function
The 12 V fuse box with distribution function distributes the incoming current to the connected consuming
units, whereby one slot with a blade fuse is provided for each consuming unit.
The fuse slots are allocated as follows:
F3
Hot water boiler (Truma heating)
F4
Electrical step
F5
Interior lighting 1
F6
Interior lighting 2
F7
Fresh water pump
F8
Exterior light
F9
Toilet + 12 V socket
F3
F4
12 V fuse box with distribution function (sample illustration)
F8
F5
F6
F7
10 A
15 A
15 A
15 A
10 A
15 A
10 A
Electrical system
F9
(red)
(blue)
(blue)
(blue)
(red)
(blue)
(red)
EN 53