Symbol on
Function
the screen
Limitation of underfloor sensor
temperature
3. LIT
Sets a temperature limit for the
underfloor sensor.
Temperature differential
The differential (hysteresis) is the
difference in temperature required for
switching the system on and off. If, for
example, you set the temperature in the
4. DIF
heating system to 20 °C and differential to
0.4 °C, the thermostat activates heating
as soon as room temperature drops to
19.6 °C and switches heating off when
temperature reaches 20.4 °C.
Low temperature protection
5. LTP
The preset temperature for this mode
is 5 °C.
6. PRG
Days of the week setting
This function is not available for this
7. RLE
thermostat
This function is not available for this
8. DLY
thermostat
Setting with up and down arrows
can be set to +5 °C to +60 °C, 1 °C
resolution
can be set to 1 °C to 10 °C, with 1 °C
resolution
Turned on or off (
screen).
programming off, manual mode
only – OFF
5 working days + 2 weekend days mode
6 working days + 1 weekend day mode
7 working days mode
12