Descargar Imprimir esta página

Amprobe SOLAR-600 Manual De Uso página 19

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Manual Scan
1. Press
2. Properly connect the pair of Kelvin clips to the solar panel and the
Analyzer. The red Kelvin clip is for positive pole and the black Kelvin clip
for negative pole.
3. Press
for scanning)
Current Range of Scan begin: 200mA
Current Range of Scan end: 548mA
After setting up the current range, press
SETUP menu.
Note: If the "Current Range of Scan begin" is over "Ishort", then the
scanning will not be performed and no result will come out.
4. Press
simulation from the BEGIN value to END value, and draw I-V / V-I curve
and P-V / P-I curve in LCD. Users can move the cursor to review each
individual values along the curve.
After the scanning is finished, the result will come out like below.
WARNING!
There is a time delay before the unit performs the "Manual Scan". This
time delay allows the light source to be turned on before "Manual Scan"
starts. Time delay can be set in the SETUP menu.
button to turn on the Analyzer.
button to enter the SETUP menu: (Type in the current range
(SCAN) button to start MANUAL SCAN. The analyzer run
button again to exit the
12

Publicidad

loading