Once the cooling countdown is over, the display shows 'OFF'.
OFF!
Push together buttons 2 and 3 to turn on the extruder again or unplug it.
WARNING! Always unplug the extruder at the end of working day.
SETTINGS MENU
Hold down button 2 within 6 seconds from connecting the extruder to the
power source to enter the settings menu.
PRE-HEATING
----------------------
260°C
215°C
WAIT .........390S
If within 6 seconds you cannot access the menu, restart the countdown.
Push buttons 6 and 7 to select the menu number to access
Push button 3 to confirm.
NUMBER?
1
WORKING HOURS
Number 1: it displays the MOTOR working hours hh: mm) with Total and
Partial time counter.
hH:mM
T
hH:mM
P
Hold pressed either button #6 or #7 to clear the partial counter.
Accomplished operations display 'SAVED!'.
CELSIUS-FAHRENHEIT TEMPERATURE
NUMBER 2: use to switch between Celsius and Fahrenheit. Use buttons 6
and 7 to select Celsius CEL or Fahrenheit FAR.
Press button 3 to save the settings.
Accomplished operations display 'SAVED!'.
2
7
3
6
7
6
STARTUP
NUMBER 10: display shows OFF! Buttons' pressing is required to start.
NUMBER 15: the extruder starts immediately after power plugin.
Accomplished operations display 'SAVED!'.
AIR-FLOW SETTING
NUMBER 45.
Use buttons #6 and #7 to set the air flow.
Press #3 to confirm.
X 1000: 23/18
▊▊▊▊▊▊▊▊▊
Accomplished operations display 'SAVED!'.
7. MAINTENANCE
Warning
•
Disconnect extruder from electrical line before performing any
maintenance intervention.
Let specialized technicians to perform maintenance on the welder.
•
Before any intervention, wait for the complete cooling of the extruder.
OPENING THE CASING
Casing and inner parts are connected. Pay attention to both cables'
and screws' position.
7
3
6
EN
21