Once the cooling countdown is over, the display shows 'OFF'.
OFF!
Push together buttons 2 and 3 to turn on the extruder again or unplug it.
WARNING! Always unplug the extruder at the end of working day.
SETTINGS MENU
Hold down button 2 within 6 seconds from connecting the extruder to the
power source to enter the settings menu.
PRE-HEATING
----------------------
260°C
215°C
WAIT .........390S
If within 6 seconds you cannot access the menu, restart the countdown.
Push buttons 6 and 7 to select the menu number to access
Push button 3 to confirm.
NUMBER?
1
WORKING HOURS
Number 1: it displays the MOTOR working hours hh: mm) with Total and
Partial time counter.
hH:mM
T
hH:mM
P
Hold pressed either button #6 or #7 to clear the partial counter.
Accomplished operations display 'SAVED!'.
CELSIUS-FAHRENHEIT TEMPERATURE
NUMBER 2: use to switch between Celsius and Fahrenheit. Use buttons 6
and 7 to select Celsius CEL or Fahrenheit FAR.
Press button 3 to save the settings.
Accomplished operations display 'SAVED!'.
2
7
3
6
7
6
STARTUP
NUMBER 10: display shows OFF! Buttons' pressing is required to start.
NUMBER 15: the extruder starts immediately after power plugin.
Accomplished operations display 'SAVED!'.
AIR-FLOW SETTING
NUMBER 45.
Use buttons #6 and #7 to set the air flow.
Press #3 to confirm.
X 1000: 23/18
▊▊▊▊▊▊▊▊▊
Accomplished operations display 'SAVED!'.
7. MAINTENANCE
Warning
Disconnect extruder from electrical line before performing any
maintenance intervention.
Let specialized technicians to perform maintenance on the welder.
Before any intervention, wait for the complete cooling of the extruder.
OPENING THE CASING
Casing and inner parts are connected. Pay attention to both cables'
and screws' position.
7