Err description
#
Err description
No feedback from the temperature sensors.
Probable cause:
5
temperature controller fault.
Contact an authorized service center
Cannot stabilize the melting chamber temperature.
Probable causes:
a.
Sudden change of working conditions (e.g. too much or too low
10
output)
b.
Temperature probe fault.
Turn off/on the extruder.
If the error persists, contact an authorized service center
Cannot stabilize the blower air temperature
Probable causes:
a.
Sudden change of working conditions (e.g. the blower hose is
clogged)
15
b.
Temperature probe fault.
Turn off/on the extruder and make sure that the air flow is not
clogged.
If the error persists, contact an authorized service center
The melting chamber temperature is too high
20
contact an authorized service center
The blower air temperature is too high
25
contact an authorized service center
Cannot control the blower
30
contact an authorized service center
The wiring bow temperature is too high (above 95°C/200F)
35
Make sure that the environmental conditions are suitable to the
extruder (e.g. avoid direct sunlight, etc..)
The specifications of the device and the data entered in
this manual are subject to change without notice from the manufacturer.
Reproduction of this manual, including in part, is
prohibited.
Full parts lists and technical documents are available online at
www.ritmo.cloud.
Help in the event of problems:
S.p.A.
via A. Volta, 35/37 - Z.I. Selve
35037 BRESSEO DI TEOLO (PD)
ITALY
Tel. +39.049.990.1888
Fax +39.049.990.1993
service@ritmo.it
DISPOSAL
Do not dispose of in the household trash. Add the device that is no
longer able to be used to a separate collection for the purpose of
environmentally friendly recycling.
Contact Ritmo S.p.A. for further info.
EN