USER INSTRUCTIONS
– In case of fault and/or incorrect equipment operation, deactivate it, without making any repairs or taking any direct action.
Apply only to qualified technical personnel.
– Boiler installation and any other assistance and/or maintenance activity must be carried out by qualified personnel per-
suant to Standard CEI 64-8. Under no circumstances, the devices sealed by the manufacturer can be tampered with.
– It is absolutely prohibited to block the intake grilles and the aeration opening of the room where the equipment is installed.
– The manufacturer shall not be held liable for any damage caused by improper use of the appliance.
– T his appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
LIGHTING AND OPERATION
BOILER IGNITION (fig. 25)
The first ignition of the boiler must be car-
ried out by qualified technical personnel.
Successively, if it is necessary to start up
the boiler again, adhere strictly to the fol-
lowing instructions: open the gas tap to
allow the flow of the fuel and move the main
switch of the system to "ON". After a stop,
wait for about 30 seconds before restoring
functioning conditions do that the boiler can
perform the control sequence.
If the green led is on, this indicates the pre-
sence of voltage.
Keys lock
If the device is not used, the keys will be
locked 15 minutes after the last setting was
made (PAR 5 by default) and the display ligh-
ATTENTION: for set up modality of function more adapted to graze the
keys simply. One beep indicates that the boiler has taken command. If
PAR 5 is disabled, the display remains lit.
WARNINGS
ting will turn off. To set one of the operating
modes, press any of the keys for more than
two seconds (the display will indicate one to
four
segments
progressively
unlocking the controls).
Winter
Press the key (
) of the controls to acti-
vate the winter mode functioning (heating
and D.H.W.). The display will be as shown in
the figure.
Summer
Press the key (
vate the summer mode functioning (only
before
the production D.H.W.). The display will be
as shown in the figure.
REGULATION OF THE WATER
TEMPERATURE FOR HEATING (fig. 26)
To set the temperature of the water for
heating, press the key (
The display will be as shown in the figure.
Change the values with the key (
ES
PT
ENG
) of the controls to acti-
) of the controls .
and
Fig. 25
83