Descargar Imprimir esta página

Cebora SYNSTAR TWIN 270 T Manual De Instrucciones página 27

Ocultar thumbs Ver también para SYNSTAR TWIN 270 T:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 67
6�1
Service functions (PROCESS PARAMS) shown on the display screen a
To access these functions, we must start from the main display page and press the knob B for at least 2 seconds.
To enter the function, simply select it by means of the knob B and press it for less than 2 seconds. To return to the main
display page, press the knob B for at least 2 seconds.
The functions which can be selected are:
• Synergic curve (Wire Selection).
To choose the synergic curve, by means of the knob B, it is necessary to select and press on the curve presented by
the display screen A. Simply select the curve of interest and confirm the choice by pressing the knob B for less than
2 seconds.
After pressing the knob B return is made to the previous display page (PROCESS PARAMS).
• Process
Use knob B to choose or confirm a welding mode by selecting and pressing Short or Pulsed (optional) for at least 2
seconds.
Short
indicates that the short synergic welding mode is selected.
Pulsed indicates that the pulsed synergic welding mode is selected (optional).
• Welding mode (Start Mode).
To choose the welding start mode 2T, 4T or 3L, select one of the 2 modes by means of the knob B and press the
knob B for less than 2 seconds to confirm the choice. This operation always returns us to the previous display page
(PROCESS PARAMS).
Mode 2T, the machine starts welding when the torch button is pressed and stops when this is released.
Mode 4T, to start welding, press and release the torch button. To complete welding, press and release again.
3301051/B
27/33

Publicidad

loading

Este manual también es adecuado para:

344