DC CURRENT LESS THAN 200mA
1. For mA DC currents less than 200mA, insert RED test lead into VΩ
jack
, and BLACK test lead into COM jack
5
Selector Switch
2. To measure current: Remove power from circuit, open circuit at
measurement point, connect meter in-series in the circuit using
the test leads, and apply power to circuit.
NOTE: If measuring mA, the Function Selector Switch
be rotated to successively lower mA DC settings to obtain higher
resolution measurements.
Do not attempt to measure more than 10A.
When measuring currents greater than 6A, a measurement
time of 30 seconds followed by 10 minutes of recovery time
is recommended.
RESISTANCE MEASUREMENTS
1. Insert RED test lead into VΩ jack
COM jack
highest Ω setting (2MΩ).
2. Remove power from circuit.
3. Measure resistance by connecting test leads to circuit and
rotating the Function Selector Switch
lower Ω settings to obtain higher resolution measurements.
Black lead
NOTE: When in a Resistance setting and the test leads are open
(not connected across a resistor), or when a failed resistor is under
test, the display will indicate O.L. This is normal.
DO NOT attempt to measure resistance on a live circuit.
OPERATING INSTRUCTIONS
to the highest mA DC setting (200mA).
2
Black lead
Red lead
, and rotate Function Selector Switch
4
Red lead
, and rotate Function
4
, and BLACK test lead into
5
to successively
2
may
2
to the
2
9