3. Start 2 sets of inverter generators. The starting operation is as the same
as normal process (refer on manual book starting parts).
Attention: Please make sure the parallel connection wires have been put
into the parallel connection sockets properly. If no connecting, starting
inverter generators could be damaged and no power.
4. Put the equipment plug 5 into socket 6, turn on the equipmentpower.
Warning:
Only 2 sets of P2000i inverter generator can be parallel connected.
More than 2 sets and above inverter generators parallel connection are not
permitted.
Only use P2000i specialized parallel connecting wire.
When use parallel connecting way for P2000i inverter generators, put the
plug into sockets safety.
Make use put the right plug into sockets for parallel connecting wire.
When working on parallel connecting way, don't put off the parallel
connecting wire. Before starting, parallel connecting wire need to be
connected firstly. Only put off the wire after inverter generator power off.
When working on parallel connecting way, No currents output when
turning off one of the inverter generators.
When only operation on one inverter generator, make sure to put off
the parallel connecting wire.
When two sets of inverter generators working independently, don't connect
the parallel connecting wire.
Read P2000i manual book carefully before operation.