Stove start-up

Before starting-up the stove complete the following procedure:
1. Insert the power supply cable.
2. Position the switch located on the back of the stove to position 1.
3. Verify that the system is connected to the chimney.
4. Load the tank with 6 mm pellet
6. Load the auger as described in the reference chapter
7. Press the P3 key for 3 seconds.
At this point the stove will complete the start-up phase. The following wording will appear on the display
• ACCENDE (Start-up)
• ATTESA FIAMMA (Awaiting flame)
• FIAMMA PRESENTE (Flame present)
• LAVORO (Operation)
During the work phase one must verify the following settings:
• IMPOSTAZIONE SET DI POTENZA (Power set settings)
• IMPOSTAZIONE SET TEMPERATURA AMBIENTE (Room temperature setting)
• IMPOSTAZIONE MISCELA PELLET/ARIA (Pellet/Air mix setting

Operational warnings

• Shut-off the stove in case of malfunction or improper functioning using the 3 key.
• Do not place pellet manually into the brazier.
• The accumulation of unburnt pellet in the brazier after multiple start-up failures must be removed before proceeding with
a new ignition - Do NOT pour unburnt pellet into the tank after a start-up failure.
• Do not place fuels different from wood pellet into the tank.
• Do not start-up the stove using flammable materials in case of start-up system malfunction.

Optional Remote Control

IR remote control to remotely operate the thermo-stove
1
2
4
3

Synthetic phase diagram

PHASE
FINAL CLEANING
START-UP
Awaiting flame
Flame present
OPERATION
Modulate work
ECO STOP
T ON
Fan awaiting start
Fan wait restart
Start-up awaiting re-start
Smoke
OFF
! IMPORTANT
STAR 10.2 C- STAR 12.2 C
Use and maintenance manual
• 1 - 2 Temperature adjustment:
• 5 - 6 Power adjustment:
• 3 ON/OFF:
6
• 4 With no function
5
DESCRIPTION
The stove is in shut-off phase and the cooling phase has not yet been completed
The spark plug pre-heat phase has started, and the pellet starts to fall in the brazier
The pellet ignites thanks to the heat of the entering air which passes through the conduit of the incan-
descent resistance
Flame is visible in the brazier
The stove has terminated the ignition phase: it is not possible to change work power
The set room temperature set has been reached.
Comfort Clima activated, set room temperature reached. The stove is off
The room probe is interrupted or an external thermostat has been connected
The stove is in cooling phase: once this condition has been reached it will start automatically
The stove is in cooling phase: once this condition has been reached it will re-start automatically
The hot re-start phase has been started. Operation is the same as the ACCENDE (Start) phase
The maximum threshold has been reached: to cool down the stove pellet load and draught is is
reduced at PT01
The stove is off
IF THE "HOT FUMI (SMOKE)" SIGNAL IS DISPLAYED, IT MEANS THERE ARE COMBUSTION
PROBLEMS. IT IS THEREFORE NECESSARY TO CONTACT THE AREA Technical After-Sales
Service C.A.T. FOR AN INSPECTION
(the wording may vary depending on the model)
allows setting the room temperature value desired, from
a maximum of 40°C to a minimum of 6°C.
allows setting the work power value from a minimum
value of 1 to a maximum value of 5.
if pressed for two seconds, the stove can be manually
switched on and off .