System Errors
System errors can occur for numerous reasons. If persistent, contact your caravan mover dealer. Use
the table below for reference and troubleshooting.
In any given LED indication, errors will be stated in the following way:
All system errors are accompanied by an alarm from the handset, this will clear alongside the flashing
after around 8 seconds, or until the error has corrected. Various errors are listed below:
(RED) LED
Status
Over Current (Motor)
2 Flashes
Over Current (Battery)
3 Flashes
Under Voltage
4 Flashes
Over Voltage
5 Flashes
Over Temperature
Critical Low Voltage
6 Flashes
Lockout
M2 Motor Driver Failure
M3 Motor Driver Failure
8 Flashes
M2 and M3 Motor Driver
Failure
Description
Possible Cause and Action
Usually caused by overworking system, avoid excess
load or steep slopes, check vehicle brakes are not
engaged.
Usually caused by a low/flat battery, check voltage.
Usually caused by an incompatible battery, or when a
charging system is in place whilst operating.
Usually caused by prolonged use on a heavy load.
- Allow 5 minutes for electronics to cool down.
- Break long periods of travel into shorter 'trips'.
Usually caused by a loose or dry connection in wiring
or use of an end of life battery.
- Ensure system is powered off, Check wiring and
terminal condition.
- Verify battery condition through proper means (do not
rely on internal caravan battery monitor).
Triggered when output voltage is not detected:
- Possible short circuit on the motor.
- Possible controller failure.
Cycle power, if problem persists, do not use again and
contact dealer for support.
EN 22

Publicidad

loading

Productos relacionados para Quattro CM-071