9.3
Installing table models
Setup
‒ horizontally and vibration free,
‒ under an extraction hood with flame-retardant filters,
‒ not on heated surfaces,
‒ not on flammable surfaces,
‒ not against flammable walls.
‒ not above heat radiating appliances, for example, above baking oven or heat cabinets.
. Remove protective film from appliance. Remove residual adhesive with cleaner or benzene.
. Use the screw feet and align the appliance horizontally.
. For standalone setup of appliances on narrow tables or base structures: Prevent the appliance
and the table or substructure from tipping over and displacement, e.g. by screwing it to the wall or
ground.
9.4
Connect the electrical power supply
● The electrical connection must be carried out in accordance with the applicable provisions of the
VDE 0100 and of the respective responsible energy supply company.
● The flexible mains lead must be at least H 07 RN-F.
● For appliances with mains sockets, the mains socket must be easily accessible.
● For safety reasons, we recommend installing a residual current circuit breaker (RCB). Important
for induction appliances: Short term delayed sensitive to all currents use FI­circuit breaker ≥ 30
mA.
● Observe the data on the type plate when making the electrical connection!
● Set the rotary switch of the appliance to OFF, only then should you plug the mains plug into a
correctly installed plug socket!
26 / 80
DANGER! Hazardous electric voltage!
Risk of electric shock that may result in serious injury or death!
● The electrical installations must only be carried out by authorized customer service
or a qualified electrician!
. Switch off the appliance and secure it against switching on!

Publicidad