16. Fix the power supply cable to the lifting wire by a
cable clamp approximately 0.8 m above the mixer.
This prevents the cable from falling down and
becoming entangled in the propeller during
operation. Connect the cable clamp to the lifting
wire above the wire clamp by a snap hook. See
fig.
Installing a
mixer. Attach the power supply
cable to the lifting wire by cable clamps placed at
1 m intervals.
15
D
E
F
17
Attaching the power supply cable to the lifting wire
Pos. Description
D
Power supply cable
E
Snap hook
F
Wire clamp
15
Lifting wire
17
Cable clamp
Mounting the lifting wire in the drum
At least three turns of wire must always
remain on the drum. Otherwise the
wire may break loose from the drum
fixation.
Follow the separate installation and op-
erating instructions for cranes.
17. Lift the complete mixer (motor bracket with motor)
using the crane and slide it over the column
profile.
18. Slowly lower the mixer into the tank and down to
its position on the depth blocker.
19. Mount the cable sock (pos. 18 in fig.
mixer) to the top fixation bracket using the
shackle, and pull the motor cable through it to the
desired position. The power supply cable should
be slightly tightened.
B
31
18
Top fixation bracket with lifting and safety wires and
cable sock
Pos. Description
B
Bolts
18
Cable sock
20
Fixation bracket
31
Hole for fastening a safety wire
Dismantle the lifting wire from the
crane before starting the mixer.
20. Dismantle the lifting wire from the winch and fit it
to the wire clamp (pos. 20 in fig.
on the top fixation bracket. Use the lifting wire as
a relief for the power supply cable. For this
reason, the lifting wire must always be tightened.
Installing a
20
Installing a
mixer)