Descargar Imprimir esta página

Grundfos AMG Serie Instrucciones De Instalación Y Funcionamiento página 31

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 188
10. Fault finding
WARNING
Electric shock
Death or serious personal injury
Before starting any work on mixers or flowmakers, disconnect the motor from the power supply or
make sure that the fuses are removed or the main switch is switched off. Make sure that the pow-
er supply cannot be switched on unintentionally. Make sure that all rotating parts have stopped
moving.
All regulations applying to mixers or flowmakers installed in potentially explosive environments must
be observed.
Make sure that no work is carried out in potentially explosive environment.
Keep a service log.
Fault
Cause
No power supply, or supply failure.
Power supply cable is damaged.
Control system is damaged.
Propeller cannot rotate freely.
Mixer or flowmaker
Stator windings are damaged.
does not start.
Motor has cut out due to overheating.
Different phase voltages.
Overload relay is set too low or is dam-
aged.
Leakage sensor cut out mixer or flowmak-
er.
Humidity in the motor.
Stator windings are damaged.
Different phase voltages.
Mixer or flowmaker
Overload relay is set too low or is dam-
starts, but stops im-
aged.
mediately.
Leakage sensor has cut out mixer or flow-
maker.
Humidity in the motor.
Propeller rotates in the wrong direction.
No or inadequate cir-
culation produced
Mixer or flowmaker runs on two phases.
even if the motor is
running.
Internal parts are worn.
Remedy
Re-establish the power supply. Start the
mixer or flowmaker manually.
Contact an authorised service work-
shop.
Contact an authorised service workshop.
Contact an authorised service workshop.
Clean the propeller blades and make sure
that the propeller can rotate freely.
Contact Grundfos.
Wait until the motor is cooled, and try to re-
start the mixer or flowmaker.
Contact an authorised service workshop.
Check the overload relay. Set the relay to
the rated current.
Contact Grundfos.
Contact Grundfos.
Contact Grundfos.
Contact an authorised service workshop.
Check the overload relay. Set the relay to
the rated current.
Contact Grundfos.
Contact Grundfos.
Interchange two phases of the main supply.
Check the electrical connections.
Replace damaged fuses.
Call an electrician.
Contact Grundfos.
31

Publicidad

loading

Este manual también es adecuado para:

Afg serie