8. Turn the motor switch to OFF.
Attaching the Suction Set
1. Attach the suction tube to the inlet valve and tighten
firmly by hand. Be sure that the threads are straight so
that the fitting turns freely.
2. Place the suction tube and the return tube into the paint.
Priming the Pump
1. Turn the pressure control knob counterclockwise to its
lowest pressure setting.
2. Turn the PRIME/SPRAY knob to PRIME (
PRIME/SPRAY
Knob
Pressure
Control Knob
3. Turn the motor switch to ON.
4. Turn the pressure control knob clockwise to between half
and full pressure. You should see the paint move through
the suction tube to the pump. Let the unit prime 1 to 2
minutes after paint begins to flow through the return tube.
CAUTION
Always reduce the pressure to zero before changing the
position of the priming knob. Failure to do so may cause
damage to the paint pump diaphragm.
CAUTION
If the pressure control knob is reduced to zero and the
PRIME/SPRAY knob is still on SPRAY (
sprayer is operating, there will be high pressure in the
hose and spray gun until the priming knob is turned to
PRIME (
) or until the spray gun is triggered to relieve
the pressure.
© 1996 Wagner Spray Tech - All rights reserved.
).
) while the
7
English
R