Press
(
1 To perform a continuity test, position the rotary switch to
2 Press
3 Press
Figure 2-15
4 Probe the test points and read the display.
The continuity function detects intermittent shorts and opens lasting as short as
1 ms. A brief short or open causes the multimeter to emit a short beep and flash.
Keysight U1271A/U1272A User's Guide
to switch between short and open states for checking normal open
Dual
E xit
) and normal close (
your multimeter as shown in
to enable the continuity test function ( ).
to switch between the short and open state.
Dual
E xit
Circuit open.
Start to capture
Short detected, beeper sounds.
Continuity operation
) contacts.
Figure
2-16.
Press
to enable the
continuity test function.
Press
to switch between
Dual
E xit
the short and open states.
Open detected, beeper sounds.
Circuit complete.
Making Measurements
/
and set up
Smart
2
75