Application
Siedle Touch 10 for Siedle Steel.
Control panel (25.7 cm/10.1") for
door communication and access
control in conjunction with the
Siedle Vario bus.
It can be used in the In-Home bus or
Access Professional system.
In conjunction with the In-Home
bus, can only be used with the
BIM 650-... bus interface module.
Depending on the functional scope
of the access control and the
intercom system, further devices are
required for management and con-
trol functions.
Electrical voltage
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualified
electrician.
Preparation
• During installation, if necessary,
the Vario bus address must be
changed using the rotary switch and
other functions must be activated via
DIL switch.
• The rotary switch and DIL switch
are located on the installation pcb
behind the camera. If there is no
camera, then the installation pcb is
located behind the dummy module
instead.
• The camera / dummy module must
be removed from the mounting
plate for settings to be made.
• Information regarding mounting
and removal of the operating panel
and function units can be found in
the product information for the door
station.
1 Address setting
(Vario bus)
If an ST(E) 10-... is to be operated
with a COM ... (code lock module)
and/or DRM ... (display call module)
on the same Vario bus line, then a
different Vario bus address must be
set for each device. This also applies
if several ST(E) 10-... are to be oper-
ated on a Vario bus line (only pos-
sible for In-Home bus).
The address can be set from 1 to 8
and may only be used once in any
one system.
Installation pcb
DIL switch 1
Use of the E/G input:
• OFF (default): in
ST(E) 10-...
• ON: via Vario bus
DIL switch 2
ON: Parallel
operation with a
ZAM 600/670-...
DIL switch
No function
3/4
Loudspeaker For acoustic feedback
when making a door
call
Red LED /
For status display
Green LED
DIL switch 1: Evaluation of the
E/G input (external message)
• If the E/G input is to be used for
functions on the ST 10-..., then DIL
switch 1 on the installation pcb must
be set to OFF (default). A button
or actuator can then be used at
the E/G input so that an action can
be triggered on the ST(E) 10-... (e.g.
external movement sensor module
for motion-controlled activation of
the control panel, or call user via
external button). The action can be
configured via the configuration
interface using a web browser.
• If an external door release button
is to be connected to the E/G input,
for example, then DIL switch 1 must
be set to ON.
DIL switch 2: Parallel operation
with ZAM 600/670-... on one
door
The status information (call, speech,
door released) is evaluated by the
Siedle Touch and output on the
display.
If a Siedle Touch and a
ZAM 600/670-... status display
module are to be connected on the
same door, parallel operation must
be activated via DIL switch 2 (to ON)
on the Siedle Touch.
Otherwise, the status information
cannot be signalled correctly.
Mounting
Recommended mounting height
approx. 1.40 m to centre of display
(depending on the local/on-site
requirements/conditions).
Avoid direct sunlight/prolonged
exposure to heat: If devices are
exposed to direct sunlight for a pro-
longed period of time, the device's
surface temperature or the tempera-
ture inside the device may exceed
the maximum permitted ambient
temperature for operation and cause
a device failure or damage to the
device. Observe the permissible tem-
perature range.
When mounting, consider the
lighting conditions, as these can
affect the legibility of the panel:
• Direct backlight
• Direct sunlight
• Reflective surfaces
• Direct light sources such as spot-
lights
Connection system
The connection to the Siedle
intercom system used (In-Home bus
or Access Professional) takes place
via the connection pcb in the door
station.
In the case of surface-mounted
door stations, the connection pcb
is located behind the door loud-
speaker.
Information about the wiring
diagrams
a) A network cable must be laid
without fail from the door station to
the distributor for configuration.
b) Terminals E and G can be option­
ally used for integrating buttons or
actuators provided by the customer
for expanding the function of the
ST(E) 10-...