AKM2G Instructions | 7 Technical Data
7.2.3.1 AKM2G-23 Derates for Different Options
De-rates are referenced to the Max Continuous Torque ΔT wdg. = 100°C
Options - No Brake
Resolver
Resolver / Seal
SFD
SFD / Seal
DSL
DSL / Seal
De-rates are referenced to the Max Continuous Torque ΔT wdg. = 100°C
Options - Brake
Resolver
Resolver / Seal
SFD
SFD / Seal
DSL
DSL / Seal
168
Kollmorgen | kdn.kollmorgen.com | August 2018
0
1000
2000
100.0%
97.6%
94.6%
98.6%
96.2%
93.0%
100.0%
97.6%
94.6%
98.6%
96.2%
93.0%
100.0%
97.6%
94.6%
98.6%
96.2%
93.0%
0
1000
2000
99.2%
96.8%
93.7%
97.8%
95.3%
92.2%
99.2%
96.8%
93.7%
97.8%
95.3%
92.2%
99.2%
96.8%
93.7%
97.8%
95.3%
92.2%
Speed: RPM
3000
4000
5000
91.5%
88.3%
85.1%
89.8%
86.5%
83.2%
91.5%
88.3%
85.1%
89.8%
86.5%
83.2%
91.5%
88.3%
85.1%
89.8%
86.5%
83.2%
Speed: RPM
3000
4000
5000
90.6%
87.5%
84.3%
89.0%
85.7%
82.3%
90.6%
87.5%
84.3%
89.0%
85.7%
82.3%
90.6%
87.5%
84.3%
89.0%
85.7%
82.3%
6000
7000
8000
81.8%
78.5%
75.1%
79.8%
76.3%
72.8%
81.8%
78.5%
75.1%
79.8%
76.3%
72.8%
81.8%
78.5%
75.1%
79.8%
76.3%
72.8%
6000
7000
8000
81.0%
77.6%
74.2%
78.9%
75.5%
71.9%
81.0%
77.6%
74.2%
78.9%
75.5%
71.9%
81.0%
77.6%
74.2%
78.9%
75.5%
71.9%